Enhancer™

  • Protocol, Manual or Handbook Protocol MSDS, Material safety data sheet MSDS CofA, Certificate of Analysis Certificate of Analysis
  • Catalog
  • Description
  • Size
  • Price
  • Action
  • Shipping Condition
  • Files
  • 786-163
  • Enhancer™ Dot Blot System

  • 1 kit
  • $731.00
  •   Add to Cart
  • Ambient
  • Protocol, Manual or Handbook MSDS, Material safety data sheet
  • 786-165NC
  • Enhancer™ membrane (Nitrocellulose, 12 x 9cm)

  • 10
  • $123.00
  •   Add to Cart
  • Ambient
  • Protocol, Manual or Handbook MSDS, Material safety data sheet
  • 786-165NY
  • Enhancer™ membrane (Nylon, 12 x 9cm)

  • 10
  • $207.00
  •   Add to Cart
  • Ambient
  • MSDS, Material safety data sheet
  • 786-164
  • Enhancer™ Sample Tubes (8 tubes/strip)

  • 60 strips
  • $95.00
  •   Add to Cart
  • Ambient
  • MSDS, Material safety data sheet
  • 786-166
  • Protein Binding Buffer

  • 500 Applications
  • $47.00
  •   Add to Cart
  • Ambient
  • MSDS, Material safety data sheet

Enhancer™ allows for the rapid application of up to 384 protein or nucleic acid samples on to a 12 x 9cm membrane for subsequent analysis.

Samples are applied to a nitrocellulose or nylon membrane by capillary action, resulting in concentration of sample due to minimal diffusion.

Enhancer™ prevents sample waste and cross contamination of samples. Grid formation allows for easy identification of samples after probing.

Each Enhancer™ is provided with a set of 12 x 8 well application strips. Enhancer™ is provided with a flip-application tray which accommodates 96 application tubes. The application tray may be flipped four times to apply 4 x 96 samples on a 12 x 9cm membrane. A total of 384 samples may be applied where spots or samples are 3-4mm apart.

Load 2-5µl samples into the sample application tubes which allow deposition of the samples on the binding membranes by a point of entry capillary action. No risk of cross contamination or waste of samples. In less than 30 minutes you can prepare a dot blot or an array of up to 384 samples.
 

Additional Images

  • figure-1
FEATURES

    • Increase dot blot sensitivity by >10 fold.
    • Apply up to 384 protein or nucleic acid samples.
    • No cross-contamination risk.
    • No expensive electronic equipment required.

APPLICATIONS

    • High throughput screening of:

    o Multiple protein samples with specific antibodies.

    o Nucleic acid samples with specific hybridization probe.

    • Production of dot blots for 1-384 samples.

    • Protein Binding Buffer: For increased protein binding efficiency.

    • Enhancer™ Sample Tubes: 8 well strips for sample application.

    • Enhancer™ Membranes: Precut nitrocellulose or nylon membranes.


Newsletter

Enter email address to receive monthly newsletter and discounts