G-Trap™ G-Acryl Desalting Columns






G-Trap™ G-Acryl Desalting columns are ready to use prepacked columns for separation of low molecular weight substances from high molecular weight substances based on size exclusion chromatography. G-Trap™ G-Acryl Desalting columns are mostly used for removal of salt or buffer exchange before or after different chromatographic steps. G-Trap™ G-Acryl Desalting columns can be used for separation of proteins based on their sizes.

G- Biosciences offer three types of desalting columns based on different exclusion limit, namely G-Trap™ G-Acryl 600 Desalting Column, G-Trap™ G-Acryl 100 Desalting Column and G-Trap™ G-Acryl 1200 Desalting Column. The characteristics of G-Trap™ G-Acryl Desalting column resin are shown below in table 2

The G-Trap™ G-Acryl columns consist of porous polyacrylamide beads that are extremely hydrophilic and essentially free of charge. The resin is compatible with the following reagents:

  • Dilute Organic Acids
  • Urea [8M]
  • Guanidine-HCl [6M]
  • Chaotropic Agents
  • Reducing Agents (DTT, 2-mercaptoethanol)
  • Detergents (SDS, CHAPS, Triton® X-100, etc)
  • Alcohols (<20%)
  • Formamide

The G-Trap™ columns are made of biocompatible polypropylene, which does not interact with biomolecules. The column has a stopper at the inlet and snap-off end at the outlet. The characteristics of the column are listed in Table1.

Table 1: G-Trap™ G-Acryl Desalting Column

Features

1 ml column

5 ml column

Column Volume

1 ml

5 ml

Column Dimensions

0.7 x 2.5 cm

1.6 x 2.5 cm

Column Hardware Pressure Limit

0.5 MPa

0.5 MPa

Column hardware

Polypropylene

Polypropylene

NOTE: The pressure over the packed volume varies depending upon the type of medium or matrix, sample or liquid viscosity, and the column tubing used.

Table 2: G-Trap™ G-Acryl Desalting Column resin

Features

G-Trap™ G-Acryl 600 Desalting Column

G-Trap™ G-Acryl 100 Desalting Column

G-Trap™ G-Acryl 1200 Desalting Column

Bead size

90-180 µm

45-90 µm

90-180 µm

Void volume

~0.3 ml for 1 ml column and ~1.5 ml for 5 ml column

Sample Load volume

0.03 ml- 0.3 ml for 1 ml column and 0.75-1.5 ml for 5 ml column

Exclusion limit (Mr)

6,000

1,800

20,000

Maximum Pressure

1 bar [0.1 MPa] (15 psi)

Recommended Flow rate

15-20 cm/hr

5-10 cm/hr

15-20 cm/hr

Chemical stability

All commonly used buffers, 8M urea, 6M guanidine hydrochloride and all non-ionic detergents. Lower alcohols such as methanol, ethanol and propanol can be added to buffers at <25% V/V

pH stability

2 to 10

Storage

20 % ethanol at 4°C to 30°C

 

Protocol
786-1616
786-1617
786-1628
786-1629
786-1637
786-1638
Material Safety Data Sheet
786-1616
English_US
Danish
Dutch
English_UK
French
German
Spanish
Norwegian
Portuguese
Finnish
Swedish
Polish
786-1617
English_US
Danish
Dutch
English_UK
French
German
Spanish
Norwegian
Portuguese
Finnish
Swedish
Polish
786-1628
English_US
Danish
Dutch
English_UK
French
German
Spanish
Norwegian
Portuguese
Finnish
Swedish
Polish
786-1629
English_US
Danish
Dutch
English_UK
French
German
Spanish
Norwegian
Portuguese
Finnish
Swedish
Polish
786-1637
English_US
Danish
Dutch
English_UK
French
German
Spanish
Norwegian
Portuguese
Finnish
Swedish
Polish
786-1638
English_US
Danish
Dutch
English_UK
French
German
Spanish
Norwegian
Portuguese
Finnish
Swedish
Polish

Write a review

Note: HTML is not translated!
Bad Good
Captcha

CONNECT WITH US